• Home
  • Solutions
    • Software Engineering
    • Embedded Systems >
      • ESP32 and STM32
    • Artificial Intelligence
    • Cybersecurity
    • Cloud
    • Big Data
    • Enterprise SCADA >
      • Communication Protocols
    • Internet of Things (IoT)
    • Block Chain
    • Robotics & Drones
  • Industries
    • HealthCare
    • Oil and Gas
    • Light Rail
    • Battery Management Systems
    • Aviation
  • About
    • About
    • Contact
  • Blog
  • Artificial Intelligence
Skynet Consulting Ltd.
  • Home
  • Solutions
    • Software Engineering
    • Embedded Systems >
      • ESP32 and STM32
    • Artificial Intelligence
    • Cybersecurity
    • Cloud
    • Big Data
    • Enterprise SCADA >
      • Communication Protocols
    • Internet of Things (IoT)
    • Block Chain
    • Robotics & Drones
  • Industries
    • HealthCare
    • Oil and Gas
    • Light Rail
    • Battery Management Systems
    • Aviation
  • About
    • About
    • Contact
  • Blog
  • Artificial Intelligence

Enterprise SCADA / ICS

Communication Protocols
Enterprise Industrial Automation - supported by SCADA (Supervisory Control And Data Aquisition) and ICS (Industrial Control System) has evolved during the past three decades and is currently viewed as the 4th generation.
Picture
From Wikipedia:
​Supervisory Control and Data Acquisition
 (SCADA) is a control system architecture that uses computers, networked data communications and graphical user interfaces for high-level process supervisory management, but uses other peripheral devices such as programmable logic controller (PLC) and discrete PID controllers to interface with the process plant or machinery. The use of SCADA has been also considered for management and operations of project-driven-process in construction.
Picture

SCADACOM - Enterprise

Enterprise SCADA systems have many common features along with fault tolerance architecture. The following shows the security manager using a module called "Session Manager" - which displays the user, role level, and the system status (synchronized between systems). The secondary window shows the current server which the client is connected to as well as giving the option to the user to switch to another available server. The final section shows the date and time - which is synchronized between all devices - clients, servers, I/O devices and typically synched against the GPS time via NTP.
Picture
Alarms are a key system feature - showing many things such as if an alarm is currently active or if it was active in the past. This is done through a few different GUI interfaces - "Current Alarm Display", "Alarm Journal", and "Alarm History".
Schematic Display is used to display the system - either in a logical display or physical model. The schematic display is used to display a manageable amount of information for the operator to see. Typical Enterprise SCADA systems would have 400-600 schematics to represent the entire system. The schematic display has static information (drawings) as well as dynamic information such as displaying the pressure or temperatures. For control elements, the operator may click on an object and this then launches a faceplate (popup).
Faceplates are key interactive screens that are used to either control something in the field or to view an input in greater detail.
Occasionally, an operator may have an interest in one or more inputs such as pressure of a pipeline at key points. The operator may request a "Trend Display" and use the display to graph object values against time. For some objects, there may be alarm levels that are configured and would also be displayed - such as "High Limit", etc.
Picture
In support of the operators and the administrators, the SCADA systems typically would have an online documentation system available.
Picture
There are other system level objects that are not characterized as alarms but rather 'status'. For these, the operators can view the "Status Report".
Picture
The other key operator / administrative tool is called the "Database Browser" - allowing the user to view the object hierarchy in the system.
Picture

RTU - Remote Terminal Units

For Enterprise SCADA systems, RTUs and PLCs were key in monitoring and controlling the remote devices and field. In the earlier years, RTUs had more features and capabilities over PLCs - however today, the two device types have virtually converged in their capabilities. The following are examples of Enterprise RTUs.​

PLC - Programmable Logic Controller

PLCs were the standard device for many years for Enterprise SCADA since their introduction in the 1980s. PLCs were produced by companies like Allen Bradley and were sold as devices that could monitor and control field devices and allow local control through an HMI (Human Machine Interface) and local logic. For example, enable the motor to open the valve until the open valve limit switch has been activated. Originally, PLCs used a common logic framework called "Ladder Logic".
Powered by Create your own unique website with customizable templates.
  • Home
  • Solutions
    • Software Engineering
    • Embedded Systems >
      • ESP32 and STM32
    • Artificial Intelligence
    • Cybersecurity
    • Cloud
    • Big Data
    • Enterprise SCADA >
      • Communication Protocols
    • Internet of Things (IoT)
    • Block Chain
    • Robotics & Drones
  • Industries
    • HealthCare
    • Oil and Gas
    • Light Rail
    • Battery Management Systems
    • Aviation
  • About
    • About
    • Contact
  • Blog
  • Artificial Intelligence